Characteristics: High strength, corrosion resistance, lightweight, and cost-effective, suitable for ambient temperature and pressure environments.
Applications: Water supply/drainage pipes, industrial drainage systems, building ventilation ducts, etc.
Limitations: Poor temperature resistance (typically ≤60°C), limited UV resistance (requires stabilizers).
Characteristics: High temperature resistance (≤93°C), strong chemical corrosion resistance (acids, alkalis, oils), excellent flame retardancy.
Applications: Chemical fluid transport, thermal pipelines, fire protection systems, and other harsh environments.
Advantages: Higher mechanical strength and longer service life compared to PVC-U.
Function: Connect, branch, or change pipe direction, including elbows, tees, flanges, couplings, etc.
Material: Typically matches the pipe material (PVC-U/C), connected via adhesives (solvent cement) or rubber seals.
Standard Design: Compliant with international dimensional specifications (e.g., ISO 4200) for interchangeability.
Types: Gate valves, butterfly valves, ball valves, check valves, etc., made of PVC-U/C or metal-lined plastics.
Function: Control flow, pressure, and medium direction, suitable for precise regulation in industrial processes.
Sealing Technology: Rubber seals or PTFE liners to meet diverse medium requirements.
Type | Product Standards |
PVC-U (DIN,ISO,GB/T)PVC-U Fittings For Industry | GB/T 4219.2-2015 |
PVC-C (DIN,ISO,GB/T)PVC-C Fittings For Industry | GB/T 18998.3-2003 |
PVC-U (DIN,ISO,GB/T)PVC-U Pipes For Industry | GB/T 4219.1-2008 |
PVC-C (DIN,ISO,GB/T)PVC-C Pipes For Industry | GB/T 18998.2-2003 |
Standards of PVC-U Material Testing | |||
|
|
|
|
| kg/m³ | 1350-1460 | GB/T 1033.1-2008 method A :impregnation |
| ℃ | ≥80 | GB/T 8802 |
| ℃ | ≥74 | GB/T 8802 |
| / |
| GB/T 8803 |
| % | ≤5 | GB/T6671-2001 method B:Oven test |
| / | No damage to the sample surface | GB/T 13526 |
| / | No crack,no leakage | GB/T6111 |
| / | No crack,no leakage | GB/T 8801 |
| / | TIR<5% | CB/T14152 |
| J/m | ≥34.7 | ASTM D256 |
| Mpa | ≥48.3 | ASTM D638 |
| Mpa | ≥2758 | ASTM D638 |
| M/M/℃ | 7x10-5 | GB/T 1036 |
Standards of PVC-C Testing Material | |||
Item | Unite | Approval Standard | Test Method |
Density | kg/m³ | 1450-1650 | GB/T 1033-1986 |
Vicat Softening Temperature(pipe) | ℃ | ≥110 | GBT 8802 |
Vika softening temperature (pipe fittings) | ℃ | ≥103 | GB/T 8802 |
LongituGB/T 4219.2al Reversion | % | ≤5 | GB/T6671-2001 |
Chlorine Concerntration | % | ≥60 | GB/T6111 |
Hydrostatic Test | - | No crack, no leakage | ISO 1167 |
Hydrostatic Reheat Test | - | No crack, no leakage | ISO 1167 |
Drop Impact Test | % | TIR≤10% | GB/T 14152 |
Oven Test | No lamination,no crack | GB/T 8803 | |
Modulus of Elasticity | - | ≥2482 | ASTM D638 |
Tensile Strength | Mpa | ≥48.3 | ASTM D638 |
Impact Strength | 5J/m | ≥80.1 | ASTM D256 |
Coefficient of Linear Expansion | m/m℃ | 7x10-5 | |
Thermal Conductivity | w/m℃ | ≤0.13 | ASTM C177 |
Flame Retardant | - | Reset to zero | UL-94 |